8 research outputs found

    Nitrogen Doping of Electrochemically Activate Carbon Screen-Printed Electrodes

    Get PDF
    Screen printed electrodes (SPEs), which are prepared by patterning conductive inks or pastes onto an insulating support (e.g., plastic film), are widely employed as sensing and biosensing platforms due to their ease of fabrication and relatively low cost. This is especially applicable to electrodes of this nature prepared with carbon-based inks (SPCEs). To date, the most successful and significant commercial application of SPEs has been as test strips for glucose meters. Despite the maturity of this technology, SPE research remains very active as improvements in sensitivity and selectivity, which often involve modifying the electrode surface, hold the key to advancing their utility in routine applications and extending their benefits to other target analytes. Recent studies in the Bishop research group have demonstrated that nitrogen-doped SPCEs (N-SPCEs) exhibit enhanced electrochemical response towards hydrogen peroxide (H2O2), a product of oxidase enzyme (e.g., glucose oxidase, lactate oxidase, etc.) reactions and a common target in biosensing strategies. The presence of nitrogen heteroatoms on the carbon surface facilitates breakage of oxygen-oxygen bonds, a key step in reduction of H2O2. Since previous studies showed only modest incorporation of nitrogen species on SPCEs prepared from commercial ink, these studies aim to investigate the possibility of enhancing N-doping by performing a simple pre-treatment strategy that reportedly increases surface oxygen content of SPCEs prior to N-doping. Since surface oxygen sites have been previously reported to be preferentially modified with nitrogen during N doping strategies, this seems like a promising technique for improving sensitivity of N-SPCEs for H2O2 reduction. To quantify the actuality of these claims, experimental groups were fabricated having undergone no enhancement, pretreatment enhancement only, nitrogen-doping enhancement only, and a combination of the pretreatment and nitrogen-doping enhancements. Here the electrochemical behaviors of pretreated SPCEs, N-SPCEs, and pretreated N-SPCEs for the detection of H2O2 by completing comparative cyclic voltammetry (CV) experiments with and without the presence of H2O2 and with it present in varying concentrations is compared. It is projected that, if successful, the fabricated electrodes that have undergone both the pretreatment protocol and the nitrogen-doping process will have an increased sensitivity and detection limit towards H2O2

    Harvesting Ultra-Low Power Wireless Signals in the GHz Range

    Get PDF
    We present methods for harvesting wireless energy as low as -30 dBm (1uW) from the 2.4 GHz frequency range (e.g. WiFi signals) with discrete components. We have constructed a proof-of-concept device which is capable of operating at -18.8 dBm (13.2 uW) with no onboard power sources, relying solely on the 2.4 GHz energy source. The device is constructed on a PCB and consists of an impedance matching network, a rectifier, and a DC-DC converter. The impedance matching network matches a 2.4 GHz 50 Ohm input source to the high impedance rectifier and provides a passive boost. The rectifier converts the AC signal from the impedance matching network to a DC signal. This DC signal feeds into the DC-DC converter subsystem which boosts the voltage from about 45 mV DC to a clean 95 mV DC output

    Harvesting Ultra-Low Power Wireless Signals in the GHz Range

    No full text
    We present methods for harvesting wireless energy as low as -30 dBm (1uW) from the 2.4 GHz frequency range (e.g. WiFi signals) with discrete components. We have constructed a proof-of-concept device which is capable of operating at -18.8 dBm (13.2 uW) with no onboard power sources, relying solely on the 2.4 GHz energy source. The device is constructed on a PCB and consists of an impedance matching network, a rectifier, and a DC-DC converter. The impedance matching network matches a 2.4 GHz 50 Ohm input source to the high impedance rectifier and provides a passive boost. The rectifier converts the AC signal from the impedance matching network to a DC signal. This DC signal feeds into the DC-DC converter subsystem which boosts the voltage from about 45 mV DC to a clean 95 mV DC output

    Two-Dose Ceftiofur Treatment Increases Cephamycinase Gene Quantities and Fecal Microbiome Diversity in Dairy Cows Diagnosed with Metritis

    No full text
    Antimicrobial resistance is a significant concern worldwide; meanwhile, the impact of 3rd generation cephalosporin (3GC) antibiotics on the microbial communities of cattle and resistance within these communities is largely unknown. The objectives of this study were to determine the effects of two-dose ceftiofur crystalline-free acid (2-CCFA) treatment on the fecal microbiota and on the quantities of second-and third-generation cephalosporin, fluoroquinolone, and macrolide resistance genes in Holstein-Friesian dairy cows in the southwestern United States. Across three dairy farms, 124 matched pairs of cows were enrolled in a longitudinal study. Following the product label regimen, CCFA was administered on days 0 and 3 to cows diagnosed with postpartum metritis. Healthy cows were pair-matched based on lactation number and calving date. Fecal samples were collected on days 0, 6, and 16 and pooled in groups of 4 (n = 192) by farm, day, and treatment group for community DNA extraction. The characterization of community DNA included real-time PCR (qPCR) to quantify the following antibiotic resistance genes: blaCMY-2, blaCTX-M, mphA, qnrB19, and the highly conserved 16S rRNA back-calculated to gene copies per gram of feces. Additionally, 16S rRNA amplicon sequencing and metagenomics analyses were used to determine differences in bacterial community composition by treatment, day, and farm. Overall, blaCMY-2 gene copies per gram of feces increased significantly (p ≤ 0.05) in the treated group compared to the untreated group on day 6 and remained elevated on day 16. However, blaCTX-M, mphA, and qnrB19 gene quantities did not differ significantly (p ≥ 0.05) between treatment groups, days, or farms, suggesting a cephamycinase-specific enhancement in cows on these farms. Perhaps unexpectedly, 16S rRNA amplicon metagenomic analyses showed that the fecal bacterial communities from treated animals on day 6 had significantly greater (p ≤ 0.05) alpha and beta diversity than the untreated group. Two-dose ceftiofur treatment in dairy cows with metritis elevates cephamycinase gene quantities among all fecal bacteria while paradoxically increasing microbial diversity

    Experimentality: The Friendly Face of Power? The Interactive New Media as Tools of Discretionary Governance and Risk Management

    No full text

    An appraisal of respiratory system compliance in mechanically ventilated covid-19 patients

    No full text
    BackgroundHeterogeneous respiratory system static compliance (CRS) values and levels of hypoxemia in patients with novel coronavirus disease (COVID-19) requiring mechanical ventilation have been reported in previous small-case series or studies conducted at a national level.MethodsWe designed a retrospective observational cohort study with rapid data gathering from the international COVID-19 Critical Care Consortium study to comprehensively describe CRS—calculated as: tidal volume/[airway plateau pressure-positive end-expiratory pressure (PEEP)]—and its association with ventilatory management and outcomes of COVID-19 patients on mechanical ventilation (MV), admitted to intensive care units (ICU) worldwide.ResultsWe studied 745 patients from 22 countries, who required admission to the ICU and MV from January 14 to December 31, 2020, and presented at least one value of CRS within the first seven days of MV. Median (IQR) age was 62 (52–71), patients were predominantly males (68%) and from Europe/North and South America (88%). CRS, within 48 h from endotracheal intubation, was available in 649 patients and was neither associated with the duration from onset of symptoms to commencement of MV (p = 0.417) nor with PaO2/FiO2 (p = 0.100). Females presented lower CRS than males (95% CI of CRS difference between females-males: − 11.8 to − 7.4 mL/cmH2O p RS was marginal (p = 0.139). Ventilatory management varied across CRS range, resulting in a significant association between CRS and driving pressure (estimated decrease − 0.31 cmH2O/L per mL/cmH20 of CRS, 95% CI − 0.48 to − 0.14, p RS (+ 10 mL/cm H2O) was only associated with being discharge from the ICU within 28 days (HR 1.14, 95% CI 1.02–1.28, p = 0.018).ConclusionsThis multicentre report provides a comprehensive account of CRS in COVID-19 patients on MV. CRS measured within 48 h from commencement of MV has marginal predictive value for 28-day mortality, but was associated with being discharged from ICU within the same period. Trial documentation: Available at https://www.covid-critical.com/study.Trial registration: ACTRN12620000421932
    corecore